EN1634 Certified 3-Hour Fire & Smoke Curtain | 600°C 180min Elevator Door Smoke Barrier

Our EN1634 certified fire and smoke curtain system delivers 180-minute fire resistance at 600°C, specifically engineered for elevator door smoke containment and fire compartmentation in commercial buildings. This gravity fail-safe smoke barrier automatically deploys upon fire alarm activation, creating a smoke-tight seal that prevents vertical smoke migration through elevator shafts while maintaining building aesthetic integrity.
Availability:
Quantity:
sharethis sharing button

FIRE RATED CURTAINS SMOKE CURTAIN APPLICATIONS

We can customize the fire curtains and smoke curtains according to your actual needs for elevator,escape route, escalators and stairs,and atrlum patio,etc.

fire smoke curtain manufacturer Europecustom fire rated smoke curtain priceFIRE RATED CURTAINSEN1634 certified smoke curtain supplierCE marked fire smoke curtain system fire rated curtainsSMOKE CURTAIN APPLICATIONS

Motor parameters
Model 10N 30N 50N
Rated Voltage 24V 24V 24V
No-load current 1A 1A 1.5A
Load Current 4A 4.5A 8A
Power 96W 108W 192W
Load weight 40KG 60KG 100KG
Load speed 23r 15r 16r
Down load weight 7.5KG 12KG 20KG
Downward speed 22r 15r 13r
Actual lifting weight 20KG 45KG 85KG

1. High-Rise Buildings: In multi-story buildings, especially those that exceed a certain height as defined by local building codes, smoke control systems are almost always required. This is because high-rise buildings present unique challenges for evacuation and firefighting operations.
2. Underground Structures: Underground parking garages, subway stations, and other subterranean spaces often require smoke control systems due to the difficulty of natural ventilation and the potential for smoke accumulation.
3. Public Assembly Areas: Venues such as theaters, stadiums, concert halls, and conference centers may need smoke control systems to ensure the rapid and safe evacuation of large numbers of people.
4. Healthcare Facilities: Hospitals and nursing homes must have reliable smoke control measures to protect vulnerable populations who may not be able to evacuate quickly or easily.
5. Educational Institutions: Schools and universities might require smoke control systems, particularly in areas with large gatherings like auditoriums and gymnasiums.
6.Industrial Facilities:Factories and warehouses with hazardous materials or complex layouts may need smoke control systems to protect workers and responders.
7. Commercial Buildings: Office complexes and shopping malls may require smoke control systems, especially if they contain atria or other open spaces that could facilitate rapid smoke spread