QLZ Series Fireproof Control System
The series of FJK-F/S-F/D-QL01 Control System adopts American Signal Microcomputer Intelligent Control System, It controls the signals sent by Smoke Sensor, Temperature Sensor or the Fireproof Center by the two procedure ways of A and B to separate the Sensor of Smoke and Temperature. Time adjustment is controlled intelligently by microcomputer study way and it is easy to operate. It also has the functions of alarm and protecting itself automatically when the wire connected to power supply is connected wrongly and overburden besides the functions of operating automatically or manual control. The main control loop is bulky and service life is long. It can control the types of Rolling Door Motor of AC380V/50Hz and 220V/50Hz. Besides; the system could be used with our company¡¯s specialized Remote Control. |
|
1. Adopt the American Microcomputer Controller, total functions.
2. Control the fireproof rolling door automatically or by manual
3. Electronic lock box programmable
4. Protect it automatically when circuit is over burden.
5. Prevent the disturbance effective. The main control loop is bulky.
6. Send the signals sent out by touch joint without source of stop, upper limit, lower limit and trouble to the center of fireproof.
7. Storage power inside. It will check the Smoke Sensor, Temperature Sensor signals and the center of fireproofs signals when out of power and to operate the functions of slipping down, stop or close according to different signals.
8. The adjustment is easy. There is ¡°up¡± ¡°down¡± and ¡°stop¡± buttons on the surface board. |
The system adopts the Smoke Sensor and Temperature Sensor separated control and the stop time adjustment is controlled intelligently by the microcomputer study way. It is easy to operate and the service life is long.
|
 |
Electic Limiter controls the time adjustment of Traditional Fireproof Rolling Door Control System with large deviation and complex operation. Also the Electric Limiter will influence the motor life when it is old. |
| |
DK-2 Fireproof Control Box
| |
1. Middle Limit Switch, precise limit, controls the middle location. The range of stopping time is 30-307 seconds.
2. The system will protect itself in one second when the wire connected to power supply is connected wrongly.
3. System Power Dissipated 15W.
4. Sound Alarm when Smoke Sensor and Temperature Sensor and power supply inside are in trouble.
5. The contain of all output joint: AC220V/10A, DC30V/1A
6. The signal sent out by the center of fireproof controlled by switch
7. Alarm sound decibel 100dB |
 |
|